English Paper

Visual detection of pandemic influenza A H1N1 Virus 2009 by reverse-transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye

Article source: Date time:2012-08-15

  J Virol Methods. 2010 Aug;167(2):214-7. Epub 2010 Apr 8.   

  Visual detection of pandemic influenza A H1N1 Virus 2009 by reverse-transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye.  
  Ma XJ, Shu YL, Nie K, Qin M, Wang DY, Gao RB, Wang M, Wen LY, Han F, Zhou SM, Zhao X, Cheng YH, Li DX, Dong XP.    
  Source  
  National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing 100052, China.    
  Abstract  
  A sensitive reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for rapid visual detection of pandemic influenza A H1N1 virus infection. The reaction was performed in one step in a single tube at 65 degrees C for 60 min with the addition of hydroxynaphthol blue (HNB) dye prior to amplification. The detection limit of the RT-LAMP assay was approximately 60 copies, and no cross-detection was observed. The assay was evaluated further with 50 clinical specimens diagnosed clinically with seasonal influenza or pandemic influenza A H1N1 virus infection. RT-LAMP with HNB dye was demonstrated to be a sensitive and easy assay for rapid detection of pandemic influenza A H1N1 virus.  
  Copyright (c) 2010 Elsevier B.V. All rights reserved.    
  PMID: 20381535 [PubMed - indexed for MEDLINE] 